INDOOR UNIT FEATURES
• Dual Barrier Coating: The patented Dual Barrier Coating reduces the collection of contaminants like dust, fibers, smoke, and oil on the inner surface of the heat pump, resulting in optimal airflow and easier maintenance.
• Econo Cool: Econo Cool temporarily and automatically adjusts the airflow based on heat exchanger temperature. The set temperature is increased slightly, which saves energy, while maintaining comfort.
• Filter: Electrostatic Enzyme filter (built-in) that is charged with static electricity and designed to attract and filter charged particles which can include airborne non-living particulates. and Microparticle filter (optional) that removes non-living particulate matter, which can include dust and smoke.
• Multiple control options including: Back-lit screen hand-held Remote Controller (provided with unit), comfort app, third-party interfaces and both wired and wireless controllers
• Multiple fan speed options: Low, Medium, High, Powerful, Auto
• Powerful Mode: Temporarily drops or raises the set point and fan speed in order to quickly bring the room to the desired temperature.
• Quiet operation: Outdoor units are as quiet as a typical conversation, and most indoor units are whisper quiet.
• Slim wall-mounted indoor units provide zone comfort control
• Smart Dry Mode: Improves humidity control with minimal over-cooling of the space
• Smart Set: recalls a preferred preset temperature setting at the touch of a button
• Wi-Fi enabled units pair with the Comfort app for complete control over temperature, fan speeds, modes, schedules, and more.
OUTDOOR UNIT FEATURES
• Blue Fin Coating: An anti-corrosion treatment applied to the aluminum fins of the heat exchanger of the outdoor unit to protect against corrosion caused by salt, sulfur, and other airborne contaminants, especially in coastal and industrial areas.
• INVERTER-driven compressor: An inverter-driven compressor generates the precise capacity needed to maintain a temperature set point.
• Powered by Outdoor Unit: The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns |
Cooling at 95F1 |
Maximum Capacity |
Btu/h |
22,000 |
|
Rated Capacity |
Btu/h |
18,000 |
|
Minimum Capacity |
Btu/h |
5,200 |
|
Maximum Power Input |
W |
2,150 |
|
Rated Power Input |
W |
1,280 |
|
Moisture Removal |
Pints/h |
3.4 |
|
Sensible Heat Factor |
- |
0.79 |
|
Power Factor [208V / 230V] |
% |
97 / 97 |
|
Heating at 47F2 |
Maximum Capacity |
Btu/h |
27,400 |
|
Rated Capacity |
Btu/h |
21,600 |
|
Minimum Capacity |
Btu/h |
6,800 |
|
Maximum Power Input |
W |
4,000 |
|
Rated Power Input |
W |
1,680 |
|
Power Factor [208V / 230V] |
% |
97 / 97 |
|
Heating at 17F3 |
Maximum Capacity |
Btu/h |
18,200 |
|
Rated Capacity |
Btu/h |
13,700 |
|
Maximum Power Input |
W |
2,900 |
|
Rated Power Input |
W |
1,460 |
|
Heating at 5F4 |
Maximum Capacity |
Btu/h |
15,200 |
|
Maximum Power Input |
W |
2,470 |
|
Heating at -5F6 |
Maximum Capacity |
Btu/h |
11,720 |
|
Heating at -10F7 |
Maximum Capacity |
Btu/h |
10,330 |
|
Efficiency |
SEER2 |
|
22.5 |
|
EER21 |
|
14.05 |
|
HSPF2 [IV] |
|
10.3 |
|
COP at 47°F2 |
|
3.77 |
|
COP at 17°F at Maximum Capacity3 |
|
1.82 |
|
COP at 5°F at Maximum Capacity4 |
|
1.8 |
|
COP at -5°F at Maximum Capacity6 |
|
1.56 |
|
COP at -10°F at Maximum Capacity7 |
|
1.46 |
|
ENERGY STAR® Certified |
|
Yes |
|
Electrical |
Voltage, Phase, Frequency |
V AC / V AC, , Hz |
208 / 230, 1, 60 |
|
Guaranteed Voltage Range |
V AC |
187 - 253 |
|
Voltage: Indoor - Outdoor, S1-S2 |
V AC |
230 |
|
Voltage: Indoor - Outdoor, S2-S3 |
V DC |
24 |
|
Short-circuit Current Rating [SCCR] |
kA |
5 |
|
Recommended Fuse/Breaker Size (Outdoor) |
A |
25 |
|
Recommended Wire Size [Indoor - Outdoor] |
AWG |
14 |
|
Indoor Unit |
MCA |
A |
1 |
|
Fan Motor Output |
W |
56 |
|
Airflow Rate at Cooling, Dry |
CFM |
324, 392, 454, 530, 650 |
|
Airflow Rate at Cooling, Wet |
CFM |
292, 353, 408, 477, 585 |
|
Airflow Rate at Heating, Dry |
CFM |
344, 392, 454, 530, 672 |
|
Sound Pressure Level [Cooling] |
dB (A) |
28, 33, 38, 44, 49 |
|
Sound Pressure Level [Heating] |
dB (A) |
28, 34, 39, 43, 48 |
|
Drain Pipe Size O.D. |
inch [mm] |
5/8 [15.88] |
|
Dual Barrier Coating on Heat Exchanger |
|
Yes |
|
External Finish Color |
|
Munsell 0.7PB 9.2/0.4 |
|
Unit Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
43-5/16 x 10-1/8 x 12-13/16 [1,100 x 257 x 325] |
|
Package Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
45-1/2 x 15-1/2 x 13-1/2 [1,160 x 400 x 340] |
|
Unit Weight |
lbs [kg] |
37 [16.50] |
|
Package Weight |
lbs [kg] |
42 [18.80] |
|
Fan Motor Type |
|
DC Motor |
|
IDU Operating Temp. Range |
Cooling Intake Air Temp [Maximum / Minimum] |
°FDB, °FWB / °FDB,
°FWB |
90, 73 / 67, 57 |
|
Heating Intake Air Temp [Maximum / Minimum] |
°FDB |
80 / 70 |
|
NOTES
1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB) 6Heating at -5°F (Indoor: 70°F DB, 60°F WB // Outdoor: -5°F DB, -6°F WB) 7Heating at -10°F (Indoor: 70°F DB, 60°F WB // Outdoor: -10°F DB, -11°F WB)
* Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode and automatically restarts at these temperatures. |
|
Outdoor Unit |
MCA |
A |
23 |
|
MOCP |
A |
40 |
|
Fan Motor Full Load Amperage |
A |
0.76 |
|
Fan Motor Output |
W |
55 |
|
Airflow Rate Cooling |
CFM |
2,202 |
|
Airflow Rate Heating |
CFM |
1,934 |
|
Defrost Method |
|
Reverse Cycle |
|
Coating on Heat Exchanger (Bluefin, Sea Coast) |
|
Yes, Yes |
|
Sound Pressure Level, Cooling1 |
dB (A) |
54 |
|
Sound Pressure Level, Heating2 |
dB (A) |
55 |
|
Compressor Type |
|
Twin Rotary |
|
Compressor Model |
|
SRB172FQHMT |
|
Compressor Oil [Type // Charge] |
Type // oz |
RM68EH // 14.5 |
|
External Finish Color |
|
Munsell 3Y 7.8/1.1 |
|
Base Pan Heater |
|
Optional |
|
Unit Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
33-1/16 x 13 x 34-5/8 [840 x 330 x 880] |
|
Package Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
38-3/4 x 16-3/4 x 40-3/4 [980 x 420 x 1,030] |
|
Unit Weight |
lbs [kg] |
116 [52.30] |
|
Package Weight |
lbs [kg] |
135 [61.20] |
|
ODU Operating Temp. Range |
Cooling Intake Maximum Air Temp [Maximum / Minimum*] |
°FDB |
115 / 14 |
|
Cooling Thermal Lock-out / Re-start Temperatures** |
°FDB |
-1 / 3 |
|
Heating Air Temp [Maximum / Minimum] |
°FDB, °FWB / °FDB,
°FWB |
75, 65 / -5, -6 |
|
Heating Thermal Lock-out / Re-start Temperatures** |
°FDB |
-14 / -4 |
|
Refrigerant |
Type |
|
R454B |
|
Pre-Charged Refrigerant Amount |
lbs, oz |
3, 12 |
|
Maximum Pre-Charged Piping Length |
ft [m] |
50 [15] |
|
Additional Refrigerant Charge Per Additional Piping Length |
oz/ft |
0.22 |
|
Piping |
Gas Pipe Size O.D. [Flared] |
inch [mm] |
1/2 [12.70] |
|
Liquid Pipe Size O.D. [Flared] |
inch [mm] |
1/4 [6.35] |
|
Maximum Piping Length |
ft [m] |
100 [30] |
|
Maximum Height Difference |
ft [m] |
50 [15] |
|
Maximum Number of Bends |
|
10 |
|
NOTES
1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB) 6Heating at -5°F (Indoor: 70°F DB, 60°F WB // Outdoor: -5°F DB, -6°F WB) 7Heating at -10°F (Indoor: 70°F DB, 60°F WB // Outdoor: -10°F DB, -11°F WB)
* Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode and automatically restarts at these temperatures. |
|