Cooling at 95F |
Maximum Capacity |
Btu/h |
10,000 |
|
Rated Capacity |
Btu/h |
9,000 |
|
Minimum Capacity |
Btu/h |
3,800 |
|
Maximum Power Input |
W |
1,070 |
|
Rated Power Input |
W |
820 |
|
Moisture Removal |
Pints/h |
1.6 |
|
Sensible Heat Factor |
- |
0.8 |
|
Power Factor [208V / 230V] |
% |
89 / 89 |
Heating at 47F |
Maximum Capacity |
Btu/h |
11,800 |
|
Rated Capacity |
Btu/h |
10,900 |
|
Minimum Capacity |
Btu/h |
4,500 |
|
Maximum Power Input |
W |
1,380 |
|
Rated Power Input |
W |
900 |
|
Power Factor [208V / 230V] |
% |
91 / 91 |
Heating at 17F |
Maximum Capacity |
Btu/h |
7,200 |
|
Rated Capacity |
Btu/h |
6,800 |
|
Maximum Power Input |
W |
1,250 |
|
Rated Power Input |
W |
850 |
Efficiency |
SEER2 |
|
18 |
|
EER2^{1} |
|
11 |
|
HSPF2 [IV] |
|
8.5 |
|
COP at 47°F^{2} |
|
3.55 |
|
COP at 17°F at Maximum Capacity^{3} |
|
1.68 |
|
ENERGY STAR^{®} Certified |
|
No |
Electrical |
Voltage, Phase, Frequency |
V AC / V AC, ø, Hz |
208 / 230, 1, 60 |
|
Guaranteed Voltage Range |
V AC |
187 - 253 |
|
Voltage: Indoor - Outdoor, S1-S2 |
V AC |
230 |
|
Voltage: Indoor - Outdoor, S2-S3 |
V DC |
24 |
|
Short-circuit Current Rating [SCCR] |
kA |
5 |
|
Recommended Fuse/Breaker Size (Outdoor) |
A |
15 |
|
Recommended Wire Size [Indoor - Outdoor] |
AWG |
14 |
Indoor Unit |
MCA |
A |
1 |
|
Fan Motor Output |
W |
30 |
|
Airflow Rate at Cooling, Dry |
CFM |
147, 210, 301, 381 |
|
Airflow Rate at Cooling, Wet |
CFM |
132, 189, 271, 343 |
|
Airflow Rate at Heating, Dry |
CFM |
147, 224, 321, 391 |
|
Sound Pressure Level [Cooling] |
dB (A) |
22, 30, 37, 43 |
|
Sound Pressure Level [Heating] |
dB (A) |
22, 30, 37, 43 |
|
Drain Pipe Size O.D. |
inch [mm] |
5/8 [15.88] |
|
Dual Barrier Coating on Heat Exchanger |
|
No |
|
External Finish Color |
|
Munsell 0.7PB 9.2/0.4 |
|
Unit Dimensions (W x D x H) |
inch x inch x inch
[mm x mm x mm] |
33 x 9 x 11-1/16 [838 x 228 x 280] |
|
Package Dimensions (W x D x H) |
inch x inch x inch
[mm x mm x mm] |
35-1/2 x 13-1/4 x 11-1/4 [900 x 340 x 290] |
|
Unit Weight |
lbs [kg] |
20 [9] |
|
Package Weight |
lbs [kg] |
23 [10.40] |
|
Fan Motor Type |
|
DC Motor |
IDU Operating Temp. Range |
Cooling Intake Air Temp [Maximum / Minimum] |
°FDB, °FWB / °FDB,
°FWB |
90, 73 / 67, 57 |
|
Heating Intake Air Temp [Maximum / Minimum] |
°FDB |
80 / 70 |
|
NOTES
^{1} Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB)
^{2} Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB)
^{3} Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB)
^{*} Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode and automatically restarts at these temperatures. |
|
|