YMGI Specifications: DC Inverter Mini Split Heat Pump-Multiple Zone-(59)4 Outdoor Units 21SEER |
Model |
Units |
WMMS-36CH-V2B(59)4 |
Cooling Capacity Rating-Standard Comp. Speed |
Btu/h |
24000 |
Min./Max. Cooling Capacity |
Btu/h |
7500 / 33000 |
Heating Capacity Rating-Standard Comp. Speed |
Btu/h |
26000 |
Min./Max. Heating Capacity |
Btu/h |
7500 / 27978 |
Max. Allowed IDU Qty./Capacity Total |
# / Btu/h |
3 / 36,000 |
EER W/W, (Btu/h)/W |
W/W |
3.66 / 12.5 |
COP W/W, (Btu/h)/W |
W/W |
3.72 / 12.70 |
SEER / HSPF |
- |
21.00 / 10.50 |
Air Flow Volume |
CFM |
2354 |
Sound Pressure / Power Level |
dB(A) |
59 / 69 |
Power Supply |
V/Ph/Hz |
208-230/1/60 |
Power Cable Conductor Minimum Size |
AWG |
AWG12, Following NEC |
Recommended HVAC Type Circuit Breaker Size |
Amp. |
30 |
Power Input Cooling / Heating / Rated |
KW |
1.92 / 2.05 / 3.60 |
Current Input Cooling / Heating / Rated |
A |
8.35 / 8.90 / 15.97 |
Compressor Type, Model |
- |
Inverter Rotarty, LD QXAS- D23zX090B |
Compressor Capacity / Input |
W |
7250 / 2550 |
Compressor RLA / LRA |
A |
15.82 / - |
Compressor Thermal Protector KINGERSONS |
- |
Exterior 1NT11L—6233 |
Compressor Crankcase Heater |
W |
40 |
Compressor Oil Type, Charge |
-, OZs |
RB68EP, 33.4 |
De-Ice/Snow Heater Power Input |
W |
96 |
De-Ice/Snow Heater Current |
A |
0.4 |
Fan Type / Qty. / Diameter-Height |
- |
Axial-flow / 1 /D550-H66mm |
Motor Model / Type |
- |
LW92K-ZL, DC |
Motor Insulation Class, Safe Class |
- |
B or E, IPX4 |
Fan Motor Drive Type, Speed |
- |
Director Drive, 800 |
Fan Motor Power Output / Input |
W |
90 / - |
Motor Full Load Amp (FLA) |
A |
- |
Condenser Materials |
- |
Aluminum Fin-Copper Tube |
Permissible Operating Pressure for the Discharge/Suction Sides |
PSI |
600 / 360 |
High/Low Pressure Overload Protector |
PSI |
580 / - |
Cooling Operation Ambient Temperature Range |
F |
0 ~ 118 |
Heating Operation Ambient Temperature Range |
F |
-4 ~ 75 |
Defrosting Method of Heat Pump in
Low Temperature Ambient |
-- |
Automatic Reversing, Fan
Cycling |
Pressure Maitenance Method in Low
Temperature Cooling |
-- |
Automatic Fan Speed Control,
Cycling |
Overload Protector |
- |
Current+Temperature |
Designed for Climate Type, Moisture Protection |
- |
T1, IPX4 |
Refrigerant, Charge |
LBs |
R410A, 4.8 |
Metering Device KINGERSONS |
- |
Electronic expansion valve |
Flare/Nut Valve Size-Liquid |
Inch |
1/4, 1/4, 1/4 |
Flare/Nut Valve Size-Gas |
Inch |
3/8, 3/8, 3/8 |
Min. Allowed Copper Line Length/Unit |
Ft. |
15 |
Max. Allowed Copper Line Length-
outdoor to last indoor unit |
Ft. |
65 |
Max. Elevation Difference Allowed-
outdoor unit is below all indoor units |
Ft. |
35, Oil Trap is Not Needed |
Max. Elevation Difference Allowed-
outdoor unit is above indoor units |
Ft. |
35, Oil Trap is Suggested
Every 18' |
Max. Copper Line Length (all together) |
Ft. |
195 |
No Additional Refrigerant Needs to be Added, If Copper Line Length Total is Less Than |
Ft. |
100 |
Refrigerant Charge Rate, If Needed, by
Weight/Ft. of Extra Liquid Line Length |
Ozs/Ft. |
2.32 |
Dimension of Unit Outline (W×D×H) |
Inch |
38.6x16.8x31.1 |
Dimension of Package (W×D×H) |
Inch |
42.6x19.2x33.7 |
Weight-Net / Gross |
LBs |
153 / 164 |
Loading Quantity (20’/40GP/40HQ) |
Units |
44 / 96 / 144 |