Processing. Please wait. Brand: YMGI Save Listing| Email Listing | Share Product Name: YMGI QUAD WMMS60CHV2B59 WMMS09EWV2B59 WMMS12EWV2B59 WMMS18EWV2B59 WMMS24EWV2B59 Ductless Split System Item#: wmms60ch59 wmms09-12k-18k-24k Reg Price: $7,316.53 Your Price: $5,226.09 Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - wmms60ch59 wmms09-12k-18k-24k Description Zone (Indoor Unit Qty.): 2-5 Zones Alll Indoor Unit Capacity Rating Total: up to 72,000 Btu/h Allowed Indoor Unit Max. Qty.: 5 Required Indoor Unit Min. Qty. 2 Outdoor Unit Models WMMS-60CH-V2B(59) 2 (1 to 5) Power Supply 208-230/1/60 Cooling Capacity* (Btu/h) Max. IDU Cap. Total 2) 72,000 Rated 1) 42,000 Min 12,000 Total Power Input in Cooling Mode* (W) Max. 5100 Rated 3950 Min. 1200 SEER 16.0 HSPF 8.2 Heating Capacity* (Btu/h) Max. IDU Cap. Total 2) 74,000 Rated 1) 46,000 Min. 10,000 Total Power Input in Heating Mode* Max. 4800 Rated 4400 Min. 1200 Liquid Valve Size 4 x 1/4" + 3/8" Gas Valve Size 2x3/8"+2x1/2"+5/8" Compressor Manufacturer/trademark Sanyo / Mitsubishi / Others Compressor Oil / FV50S / L.R.A. (A) 55 Compressor RLA (A) 13 Compressor Power Input (W) 3000 MCA (A) 40 Fuse or Circuit Breaker (HVAC Type) 40-All IDUs EW / 50-All IDUs EC or EU Throttling Method Electronic Expansion Valve Starting Method Transducer starting Recommended Working Ambient Temp Ranges (F) AC: 20 to 115 HP: 5 to 75 Condenser Aluminum fin-copper tube Output of Fan Motor (W) 140 Fan Motor RLA (A) 1.1 Fan Motor Capacitor (uF) 6 Air Flow Rate of Outdoor Unit / Fan Type-Piece Axial fan 1 Fan Diameter (Inches) 22.5 Defrosting Method Auto Defrost Climate Type T1 Isolation I Moisture Protection IP24 Max. Operating Pressure at High Side (PSI) 550 Max. Operating Pressure at Low Side (PSI) 175 Sound Pressure Level dB (A) (H/L) 56/54 Sound Power Level dB (A) (H/L) 66/64 Dimensions of Outdoor Unit (W x H x D) (Inches) 42.25 X 43.5 X 17.5 Dimensions of Package (W x H x D) (Inches) 46.0 X 48.6 X 19.4 Net Weight /Gross Weight (LBs) 225 / 248 Refrigerant /Factory Pre-Charge for 25' (LBs) R410A / 10.6 Loading Quantity 20' Container 50 40' Container 100 40' High Cube Container 100 Important Notes The rated performance data printed on the unit nameplate are tested per AHRI 210/240 standards at standard indoor & outdoor conditions and standard installation set-up. Actually the DC inverter outdoor unit will modulate to match whatever capacity needs called/requested from indoor unit side, to produce a wide range of capacities, minimum could be about 15% of the rated number and maximum could be around 160% of the rated number. Once the DC inverter system is installed, each indoor unit's output and so the outdoor unit performance will all vary over the operation period: soft-starting, turbo quick cooling/heating, maintaining, defrosting, switching, and other condition changes. Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting pipe length/ bending, elevation difference between indoor and outdoor units, refrigerant charging level, vacuum level, leakage, air or moisture or contamination level, foreign substance left in the piping, indoor filter clean level, indoor and outdoor coil conditions, and other factors such as zoning factor ZR (=max. zone capacity sub-total / all zone capacity total). Item 24000 BTU Indoor Unit WMMS-24EW-V2B(59)(2) Power Supply 208-230/1/60 Total Capacity (Btu/h)(High/Standard/Low) AC:25000/21500/9600 HP: 26000/25600/11200 Nominal heating Capacity 26000 Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) 17800 Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD5F) 15400 SEER 18.0 HSPF 8.2 Dehumidifying Volume (Pints/Hr.) 4.2 Fan Motor Speed (RPM) (SH/H/ML) 1400/1150/1100/850 Air Flow Volume 560/471/412/353 Output of Fan Motor (W) 35 Input Power of Heater (W) / Fan Motor Capacitor (uF) 2.5 Fan Motor RLA (A) 0.45 Fan Type-Piece Cross flow fan -1 Fan Wheel Diameter x Length (inches) 3.9 x 30.1 Evaporator Heat Exchanger Type Aluminium fin-copper tube Connection Copper Size Liquid/Gas (Inches) 1/4 + 5/8 Swing Motor Model MP35XX Output of Swing Motor (W) 2.5 Fuse (A) PCB 3.15A Transformer 0.2A Sound Pressure Level db (A) (H/M/L) 48 / 44 / 40 / 35 Sound Pressure Level db (A) (H/M/L)*** 58 / 54 / 50 / 45 Dimensions of Indoor Unit (W x H x D) (Inches) 39.7 x 12.4 x 8.6 Dimensions of Indoor Unit Package(W x H x D) (Inches) 42.2 x 15.6 x 12.3 Net / Gross Weight (LBs) 35.3 / 46.3 Loading Quantity 20' Container 47 40' Container 96 40' HQ Container 114 Item sold by www.kingersons.com, one stop online ac systems store. Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 3 + 1 Send Shop for YMGI and browse manuals and details of wmms60ch59 wmms09-12k-18k-24k 24 Hour AC Repair Southfield, MI HVAC Contractors Valley Stream, NY AC Service Beaumont, TX HVAC Contractors Revere, MA AC Companies Missoula, MT Certified Electrician Bremerton, WA Top Watch This Item Your Phone Number: Your Email: Message here: Make an offer Quantity you would like to buy: 1 2 3 4 5 6 7 8 9 10 How much would you like to pay for each unit: Type your Message: Shipping Address: URL of the website where you saw cheaper price Or better deal: Your email address: Your phone number: E-mail a friend about this item Your friend email: Your Email: Message here: Email For Price Your Phone Number: Your Email: Shipping Zip Code: How soon do you need this product?: Immidiately Within a week Within couple of months Just looking for price Message here:
Brand: YMGI Save Listing| Email Listing | Share Product Name: YMGI QUAD WMMS60CHV2B59 WMMS09EWV2B59 WMMS12EWV2B59 WMMS18EWV2B59 WMMS24EWV2B59 Ductless Split System Item#: wmms60ch59 wmms09-12k-18k-24k Reg Price: $7,316.53 Your Price: $5,226.09 Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required
Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - wmms60ch59 wmms09-12k-18k-24k Description Zone (Indoor Unit Qty.): 2-5 Zones Alll Indoor Unit Capacity Rating Total: up to 72,000 Btu/h Allowed Indoor Unit Max. Qty.: 5 Required Indoor Unit Min. Qty. 2 Outdoor Unit Models WMMS-60CH-V2B(59) 2 (1 to 5) Power Supply 208-230/1/60 Cooling Capacity* (Btu/h) Max. IDU Cap. Total 2) 72,000 Rated 1) 42,000 Min 12,000 Total Power Input in Cooling Mode* (W) Max. 5100 Rated 3950 Min. 1200 SEER 16.0 HSPF 8.2 Heating Capacity* (Btu/h) Max. IDU Cap. Total 2) 74,000 Rated 1) 46,000 Min. 10,000 Total Power Input in Heating Mode* Max. 4800 Rated 4400 Min. 1200 Liquid Valve Size 4 x 1/4" + 3/8" Gas Valve Size 2x3/8"+2x1/2"+5/8" Compressor Manufacturer/trademark Sanyo / Mitsubishi / Others Compressor Oil / FV50S / L.R.A. (A) 55 Compressor RLA (A) 13 Compressor Power Input (W) 3000 MCA (A) 40 Fuse or Circuit Breaker (HVAC Type) 40-All IDUs EW / 50-All IDUs EC or EU Throttling Method Electronic Expansion Valve Starting Method Transducer starting Recommended Working Ambient Temp Ranges (F) AC: 20 to 115 HP: 5 to 75 Condenser Aluminum fin-copper tube Output of Fan Motor (W) 140 Fan Motor RLA (A) 1.1 Fan Motor Capacitor (uF) 6 Air Flow Rate of Outdoor Unit / Fan Type-Piece Axial fan 1 Fan Diameter (Inches) 22.5 Defrosting Method Auto Defrost Climate Type T1 Isolation I Moisture Protection IP24 Max. Operating Pressure at High Side (PSI) 550 Max. Operating Pressure at Low Side (PSI) 175 Sound Pressure Level dB (A) (H/L) 56/54 Sound Power Level dB (A) (H/L) 66/64 Dimensions of Outdoor Unit (W x H x D) (Inches) 42.25 X 43.5 X 17.5 Dimensions of Package (W x H x D) (Inches) 46.0 X 48.6 X 19.4 Net Weight /Gross Weight (LBs) 225 / 248 Refrigerant /Factory Pre-Charge for 25' (LBs) R410A / 10.6 Loading Quantity 20' Container 50 40' Container 100 40' High Cube Container 100 Important Notes The rated performance data printed on the unit nameplate are tested per AHRI 210/240 standards at standard indoor & outdoor conditions and standard installation set-up. Actually the DC inverter outdoor unit will modulate to match whatever capacity needs called/requested from indoor unit side, to produce a wide range of capacities, minimum could be about 15% of the rated number and maximum could be around 160% of the rated number. Once the DC inverter system is installed, each indoor unit's output and so the outdoor unit performance will all vary over the operation period: soft-starting, turbo quick cooling/heating, maintaining, defrosting, switching, and other condition changes. Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting pipe length/ bending, elevation difference between indoor and outdoor units, refrigerant charging level, vacuum level, leakage, air or moisture or contamination level, foreign substance left in the piping, indoor filter clean level, indoor and outdoor coil conditions, and other factors such as zoning factor ZR (=max. zone capacity sub-total / all zone capacity total). Item 24000 BTU Indoor Unit WMMS-24EW-V2B(59)(2) Power Supply 208-230/1/60 Total Capacity (Btu/h)(High/Standard/Low) AC:25000/21500/9600 HP: 26000/25600/11200 Nominal heating Capacity 26000 Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) 17800 Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD5F) 15400 SEER 18.0 HSPF 8.2 Dehumidifying Volume (Pints/Hr.) 4.2 Fan Motor Speed (RPM) (SH/H/ML) 1400/1150/1100/850 Air Flow Volume 560/471/412/353 Output of Fan Motor (W) 35 Input Power of Heater (W) / Fan Motor Capacitor (uF) 2.5 Fan Motor RLA (A) 0.45 Fan Type-Piece Cross flow fan -1 Fan Wheel Diameter x Length (inches) 3.9 x 30.1 Evaporator Heat Exchanger Type Aluminium fin-copper tube Connection Copper Size Liquid/Gas (Inches) 1/4 + 5/8 Swing Motor Model MP35XX Output of Swing Motor (W) 2.5 Fuse (A) PCB 3.15A Transformer 0.2A Sound Pressure Level db (A) (H/M/L) 48 / 44 / 40 / 35 Sound Pressure Level db (A) (H/M/L)*** 58 / 54 / 50 / 45 Dimensions of Indoor Unit (W x H x D) (Inches) 39.7 x 12.4 x 8.6 Dimensions of Indoor Unit Package(W x H x D) (Inches) 42.2 x 15.6 x 12.3 Net / Gross Weight (LBs) 35.3 / 46.3 Loading Quantity 20' Container 47 40' Container 96 40' HQ Container 114 Item sold by www.kingersons.com, one stop online ac systems store. Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 3 + 1 Send Shop for YMGI and browse manuals and details of wmms60ch59 wmms09-12k-18k-24k 24 Hour AC Repair Southfield, MI HVAC Contractors Valley Stream, NY AC Service Beaumont, TX HVAC Contractors Revere, MA AC Companies Missoula, MT Certified Electrician Bremerton, WA Top